Sharp MD-X60 Service Manual page 76

Table of Contents

Advertisement

MD-X60
IC901 RH-iX2757AFZZ:System Control Micon (2/4)
Pin No.
Terminal Name
27
TRAY MOTOR
28
FLD RESET
29
CAM SW1
30
CAM SW2
31
CAM SW3
32
CAM SW4
33
CAM SW-A
34
CAM SW-B
35
CAM SW-C
36
CAM SW-D
37
38
MAIN CLK
39
MAIN CLK
40
41
SUB CLK
42
SUB CLK
43
RESET
44
RX IN
45
PROTECT
46
NAME IN
47
SPEANA-A
48
SPEANA-B
49
SPEANA-C
50
DSTB
51
52
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Port Name
Input/Output
P94
Output
P95
Output
P120/RTP0
Input
P121/RTP1
Input
P122/RTP2
Input
P123/RTP3
Input
P124/RTP4
Input
P125/RTP5
Input
P126/RTP6
Input
P127/RTP7
Input
VDD
X2
X1
Input
VSS
XT2
XT1
Input
RESET
Input
P00/INTP0
Input
P01/INTP1
Input
P02/INTP2
Input
NM1
P03/INTP3
Output
P04/INTP4
Output
P05/INTP5
Output
P06/INTP6
Input
AVDD
AVREFO
Input
Setting
Active
in Reset
Level
L
H
TA7291S IN1 control. Refer to the true value table.
For Nch open drain, the external pull-up is required
IN1
L
L
Reset output to M35500AFP/M66004FP
L
Detection input of cam SW1 to cam SW4
L: SW ON H: SW OFF
L
14 cam positions (drum positions) are detected by using the
combination of SW1 to 4.
L
L
_
H
Main tray OPEN completion detection SW input
H: SW OFF (OPEN completion state)
L: SW ON (other state)
The CLOSE function is given with this SW when the tray lid is
pressed.Main tray OPEN completion detection SW input
L
Main tray CLOSE completion detection SW input
L: SW ON (CLOSE completion state)
H: SW OFF (other state)
L
Sub-tray storage completion detection SW input
L: SW ON (storage completion state)
H: SW OFF (other state)
H
Sub-tray SET completion detection SW input
H: SW OFF (SET completion state)
L: SW ON (other state)
Connected to VDD
6 Mhz sera-lock
6 Mhz sera-lock
Ground potential To be connected to VSS
32.768 kHz crystal
32.768 kHz crystal
L
H
Reset input
L
H
Remote control input
L
H
POWER AMP state abnormal detection input.
Abnormal sate: L
L
H
TEXT input from external MD
L/H
L
Control of MPX part of BA3835S
L/H
L
L/H
L
L/H
L
Strobe input from MD microcomputer. Interruption input
A/D converter analog power supply. To be connected to VDD
A/D converter reference voltage input. To be connected
toVDD..
– 76 –
Function
INPUT
OUTPUT
IN2
OUT1 OUT2
0
0
1
0
H
L
CW(FORWARD)
0
1
L
H
CCW(REVERSE)
1
1
L
L
BA3835S
A
B
C
AOUT
L
L
L
L
L
H
105Hz
L
H
L
340Hz
L
H
H
H
L
L
H
L
H
H
H
L
3.4kHz
H
H
H
10.5kHz
MODE
STOP
BRAKE
GND
GND
1kHz
GND

Hide quick links: