5. Convergence Errors.
If an error message or code appears while performing MAGIC FOCUS or initialize (PIP MODE, PIP CH in DCU
service mode) follow this confirmation and repair method.
1. Turn on power and receive any signal.
2. Press service switch on Power/Deflection board.
3. Press "SWAP" then "PIP CH" on remote control.
4. Error code will be displayed in bottom right corner of screen. If there is no error, an "INITIAL OK" message will
appear on screen.
ERROR!!
5. Follow repair table for errors.
Error
Error
Display
Code
Code
1
VF Error
2
Connect 1
*2
3*2
A/D Level
4
Over Flow
5
Convergence
7
Operation
9
Connect 2
10
Noise
11
Sync
*1 -- RK 41, 46, 50, 54, 58, 62 check these resistors.
*2 Sensor Position
Error code
X
DCU REPAIR TABLE
Countermeasure
Replace DCU
1. Darken Outside Light
2. Placing of sensor
3. Is pattern hitting sensor
4. Check connection and solder bridge of sensor
5. Replace sensor
6. Replace sensor P.W.B.
7. Sensor Connector check
8. Replace DCU
9. Adjustment check (H/V size, centering)
Same as Error Code 2
1. Check the placement of sensor
2. Adjustment check (H/V size, centering)
3. Conv. amp. gain check *1 (check resistor values only)
Same as Error Code 4
Same as Error Code 4
Same as Error Code 2
Input strong field signal
Check the wiring of connector between sensor and DCU
Input strong field signal
Check the wiring of connetor between sensor and DCU
7
CONNECT 1!
No. 1
3
1
(View from front side)
3
5
40
Error message
Sensor position
Application
Magic
Initialize
Focus
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X