Precor C966i Service Manual page 22

Hide thumbs Also See for C966i:
Table of Contents

Advertisement

Diagram 5.4 - Power Control Module Connector Numbering
4.
If the incline moves normally skip to step 7.
5.
If the display indicates that the incline should be moving and the incline motor does not
move and AC line voltage is present, skip to step 12.
6.
If the display indicates that the incline should be moving and the incline motor does not
move and AC line voltage is not present, replace the power control module.
7.
With the incline above 0%, connect an AC voltmeter between terminals 1 & 5 of the
INCLINE connector. See Diagrams 5.3 and 5.4. Set the treadmill in the manual program and
press the INCLINE
240 Vac). Note that the AC line voltage reading will only be present before an error condition
is displayed.
8.
If the incline moves normally skip to step 11.
9.
If the display indicates that the incline should be moving and the incline motor does not
move and AC line voltage is present, skip to step 12.
10. If the display indicates that the incline should be moving and the incline motor does not
move and AC line voltage is not present, replace the power control module.
11. The incline is moving normally in both directions, there is either is not an incline problem or
the problem is intermittent. Intermittent problems are often caused by poor connections or
wiring problems.
Page 1-22
key. The AC voltmeter should read AC line voltage (either 120 Vac or
C956i, C966i (Gen 06) Treadmill
Page 22