Burner And Inner Door/Gasket Removal, Inspection Replacement And Reinstallation - Bradford White U2TW75T*RN Service Manual

Gas water heaters u ttw 75 series
Table of Contents

Advertisement

R
U TTW SERVICE PROCEDURE I
Burner and Inner Door/Gasket Removal,
Inspection, Replacement and Reinstallation
Inner Door Removal Procedure
Step 1.
Position gas control power switch to the "OFF"
position and unplug heater from wall outlet.
Step 2.
Remove outer jacket burner access door.
Step 3.
Remove wire clip from main burner feedline.
Step 4.
Inner Door Removal.
a) Disconnect the spark igniter/flame sensor wire and the
simulated resistive device from the gas control (see photo 1).
b) Disconnect main burner feed line (¾" wrench), pilot tube
(7/16" wrench) and igniter wire from gas control (see photo 2).
c) Remove (2) ¼" hex drive screws from right side inner door
(see photo 3).
d) Remove (2) ¼" hex drive screws from flange section of
inner door (see photo 3).
e) Remove (3) 1/4" hex drive screws from burner door
(see photos 4&5). The burner door and burner are
one-piece.
Flange Hex
Drive Screws
Position #2
Position #3
f) Remove burner and inner door and inspect per step 5.
Step 5. Fully inspect burner door and right side inner door gaskets for the following:
>Tears
>Missing Material
>Cracks
>Dirt or debris
If the gasket is not effected by any of the above, gasket replacement is not required. If replacement is
required, proceed to Inner Door Gasket Replacement Procedure.
Page 14
14
3
Right Side
Hex Drive
Screws
Burner Door
Hex Drive
Screws
4
>Other imperfections that will inhibit proper seal
>Gasket adhesion to inner door
>Material left on combustion chamber (around opening)
Gas Control shown in the "OFF" position
Spark Igniter/
Flame Sensor
Wire
2
Pilot Tube
Igniter Wire
5
1
Simulated Resistive
Device
Main Burner
Feedline
Position #1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Utw475s76r*n

Table of Contents