Tag Addresses
3A
Output 3A
Display
Configuration Tab
Parameter Description
Module identity
0:
None
1:
Relay output
2:
DC output non-isolated
3:
Logic/PDSIO output
4:
Logic input
5:
Triac output
6:
DC input
10: Error/Bad module
11: DC retransmission
12: DC output isolated
13: Transmitter power supply
14: Pot input (valve position)
Module function
For
=
0:
None
1:
Digital output
2:
Heating output
3:
Cooling output
For
=
or
16: None
17: Heating output
18: Cooling output
19: Retransmission of PV
20: Retransmission of SP
21: Retransmission of error
22: Retransmission of OP power
For
=
160: None
161: Remote setpoint
162: Feedforward input
163: Remote OP power high
164: Remote OP power low
165: Valve position
For
=
32:
None
33:
Remote setpoint
34:
Feedforward input
35:
Remote output power max.
36:
Remote output power min.
37:
PV = highest of ip1 or ip2
38:
PV = lowest of ip1 or ip2
39:
Derived function
40:
Select ip1 or ip2
41:
Transition of control - ip1-ip2
input type (input 2)
Refer to input configuration for all
types +
Cold junction compensation (ip 2)
Refer to input config. for types
Sensor break impedance (input 2)
Refer to input config. for types
Input value low
Input value high
Input module 3A low value
Input module 3A high value
Module 3A low value
Potentiometer input 3A low scalar
Module 3A high value
Potentiometer input 3A high scalar
Units 3A
1:
Volts
2:
mA
Minimum electrical output
Maximum electrical output
8-12
Tag
Address
12800
12803
or
12830
12831
12813
12819
12818
12829
12828
12815
12827
12814
12826
12812
12817
12816
2408 f & 2404 f PROFIBUS Communications Handbook
Sense of output
0:
Normal
1:
Inverted
Summary output 3A configuration
Program summary output 3A
config
3B
Output 3B
Display
Configuration Tab
Parameter Description
Module 3B identity
Module 3B function
Sense of output
(nor/inv as 3A)
Summary of 3B configuration
Summary program O/P 3B config.
3C
Output 3C
Display
Configuration Tab
Parameter Description
Module 3C identity
Module 3C function
Sense of output
(nor/inv as 3A)
Summary of 3C configuration
Summary program O/P 3C config.
4A
Output 4A
Display
Configuration Tab
Parameter description
Module identity
0:
None
1:
Relay output
Module function
0:
None
1:
Digital output
2:
Heating output
3:
Cooling output
Input module 4A low value
Input module 4A high value
Minimum electrical output
Maximum electrical output
Sense of output
(nor/inv as 3A)
Summary output 4A configuration
Program summary output 4A
config
Pass
Password
Display
Configuration Tab
Parameter Description
Access Mode Password
Configuration Level Password
2408 f & 2404 f PROFIBUS Communications Handbook
12809
12806
12823
Tag
Address
12801
12804
12810
12807
12824
Tag
Address
12802
12805
12811
12808
12825
Tag
Address
12864
12867
12879
12878
12881
12880
12873
12870
12887
Tag
Address
514
515

Advertisement

Table of Contents