26 inteRnAl WiRinG

The Logic + Combi boiler comes pre-fitted with 1.8m of
mains cable. This must be connected to a permanent live
supply and NOT switched by thermostats/programmers.
For installers wishing to change this cable refer to Frame
28. If the supply cord is damaged, it must be replaced
by the manufacturer, service agent or similarly qualified
persons in order to avoid hazard.
The Logic + Combi boiler comes pre-fitted with a link
wire between the room thermostat/Timer connections on
the terminal strip. This creates a permanent call for heat
and must be removed when adding a room thermostat/
programmer.
The terminal block cover carries two spare fuses for the
main PCB.
To add thermostat/programmer:
1. Isolate the mains supply to the boiler.
2. Remove the front panel. Refer to Frame 39.
3. Swing the control box down into the servicing position.
Refer to Frame 45.
4. Route incoming cables through the grommets in
bottom panel (note, grommets are 'blind' and will
require puncturing) and secure using clamps and
screws provided in hardware pack.
5. Pull off rubber terminal block cover.
6. Connect wires to terminal block, as shown below
7. Re-assemble in reverse order.
Ideal offer 6 kits as follows:
(see individual kits for installation instructions)
Mechanical Timer (24 hr) Kit - 24 hour mechanical CH timer fits into the control box of the boiler. This can be
fitted in conjunction with a room thermostat.
Electronic Timer (7 day) kit - 7 day electronic CH timer fits into the control box of the boiler. This can be fitted
in conjunction with a room thermostat. Features English language installation help messages.
RF Mechanical Programmable Room Thermostat (24 hr) kit - Combined 24 hour mechanical timer and
room thermostat with wireless communication to receiver unit which fits into control box of the boiler.
RF Electronic Programmable Room Thermostat (7 day) kit - Combined 7 day timer and room thermostat
with wireless communication to receiver unit which fits into control box of the boiler. Features English language
installation help messages. Also OpenTherm Control for gas consumption saving.
RF Mechanical Timer and Room Stat Kit - Combined mechanical timer and RF receiver. This kit fits into the
control box of the boiler. The digital RF Room thermostat can be wall mounted or free standing.
Weather Compensation Kit -
Allows outside temperature sensing.
+
Ideal Logic
Combi -
INSTALLATION
Installation and Servicing
Spare PCB fuses