Mitsubishi Electric MSH-07NV Service Manual page 68

Split-type,heat pump air conditioners wireless type
Table of Contents

Advertisement

11-5 MUH-24NV-
E1
OUTDOOR UNIT
OPERATING PROCEDURE
1. Removing the electrical parts
( 1 ) Remove the screws and the top panel.
( 2 ) Remove the screw of the cover panel. To remove the
cover panel, pull it toward you and unhook the catch-
es from the side panel.
( 3 ) Remove the screw of the service panel. To remove the
service panel, pull it down toward you and unhook the
catches on the both sides.
2. Removing the fan motor
( 1 ) Remove the screws of the front panel.
Open the front panel to a 45-degree angle.
Then lift it and unhook the catches to remove.
( 2 ) Remove the propeller nut and the propeller fan.
( 3 ) Remove the screws and the fan motor.
Disconnect the lead connectors.
68
MUH-24NV-
E2
PHOTOS
Photo 1
Screws
Front panel
Photo 2
Transformer
Outdoor controller
board
Screws
Photo 3
Motor support
Propeller
fan
Propeller nut
Top panel
Service panel
Panel cover
Capacitor
Contactor
Overcurrent
relay
Terminal block
Separator support
Lead
connectors
Valve bed