Console Redirection Settings; Flow Control - Gigabyte MW50-SV0 User Manual

Lga2011 sockets r3 motherboard for intel e5-1600 v3/e5-2600 v3 series processo
Table of Contents

Advertisement

COM1/COM2/Serial Over LAN Console Redirection Settings
Console Redirection
Select whether to enable console redirection for specified device. Console redirection enables users to
manage the system from a remote location.
Options available: Enabled/Disabled. Default setting is Disabled.

Console Redirection Settings

Terminal Type
Select a terminal type to be used for console redirection.
Options available: VT100/VT100+/ANSI /VT-UTF8. Default setting is ANSI.
Bits per second
Select the baud rate for console redirection.
Options available: 9600/19200/38400/57600/115200. Default setting is 115200.
Data Bits
Select the data bits for console redirection.
Options available: 7/8. Default setting is 8.
Parity
A parity bit can be sent with the data bits to detect some transmission errors.
Even: parity bi is 0 if the num of 1's in the data bits is even.
Odd: parity bit is 0 if num of 1's in the data bits is odd.
Mark: parity bit is always 1. Space: Parity bit is always 0.
Mark and Space Parity do not allow for error detection.
Options available: None/Even/Odd/Mark/Space. Default setting is None.
Stop Bits
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning). The standard
setting is 1 stop bit. Communication with slow devices may require more than 1 stop bit.
Options available: 1/2. Default setting is 1.

Flow Control

Flow control can prevent data loss from buffer overflow. When sending data, if the receiving buffers are
full, a 'stop' signal can be sent to stop the data flow. Once the buffers are empty, a 'start' signal can be
sent to re-start the flow. Hardware flow control uses two wires to send start/stop signals.
Options available: None/Hardware RTS/CTS. Default setting is None.
VT-UTF8 Combo Key Support
Enable/Disable VT-UTF8 Combo Key Support.
Options available: Enabled/Disabled. Default setting is Enabled.
Recorder Mode
When this mode enabled, only text will be send. This is to capture Terminal data.
Options available: Enabled/Disabled.
Default setting is Disabled.
Resolution 100x31
Enables or disables extended terminal resolution. Default setting is Enabled.
Options available: Enabled/Disabled.
(Note) Advanced items prompt when this item is defined.
BIOS Setup
(Note)
(Note)
(Note)
(Note)
- 44 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mw70-3s0

Table of Contents