Main CBA Bottom View
CAUTION !
Fixed voltage power supply circuit is used in this unit.
If Main Fuse (F601) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
CAUTION
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD,
REPLACE ONLY WITH THE SAME TYPE FUSE.
PIN 1
OF CN303
INTELLIGENT
MONITOR
WF11
PIN 7
OF IC301
WF10
PIN 13
OF IC301
WF 7
PIN 52
OF IC301
C762
1-8-30
WF 2
WF 9
WF 4
PIN 29
PIN 8
PIN 48
OF IC401
OF IC401
OF IC401
1-8-31
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT, AN ISOLATION TRANSFORMER MUST BE USED.
ALSO, IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY, WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT, A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
NOTE :
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
WF18
PIN 59
OF IC201
WF17
PIN 58
OF IC201
1-8-32
BT6300F01011-A