Weld Input/Output Cables For Resistance Grid (Dual Model Shown) - Miller Electric MOG-250 Owner's Manual

Multiple operator resistance grids (mog), racks, and remote controls
Table of Contents

Advertisement

3-3. Weld Input/Output Cables For Resistance Grid (Dual Model Shown)

2
5
Tools Needed:
OM-808 Page 12
9
8
4
1
8
11
6
7
Or
Y Turn Off welding power
source, and disconnect in-
put power before making any
weld output connections.
1
Weld Input Cable
2
Work Cable
3
Weld Output Cable
If necessary, use Section 3-7 to
select proper cable size.
Use shortest cables possible.
Do not use damaged cables.
4
Terminal Lug
Use lugs of proper amperage ca-
pacity and hole size for connecting
to common work, electrode hold-
er(s), and weld output terminals (if
applicable).
5
Common Work Connection
Connect work cable to common
work according to codes.
6
Insulated Electrode Holder
7
GTAW Torch
Install according to manufacturer's
instructions.
8
Female Camlok Connector
Install onto weld input cable as
shown in Section 3-5.
10
9
Weld Input Receptacle
Connect cable to weld input recep-
tacle on rear panel of grid.
4
10 Male Camlok Connector
Install onto weld output cable as
shown in Section 3-6.
11 Electrode Receptacle
3
Connect electrode holder cable to
Electrode receptacle.
S-0793