Electrical Service Guide; Selecting A Location And Connecting Input Power - Miller Electric M-15 Owner's Manual

Arc welding power source and wire feeder
Hide thumbs Also See for M-15:
Table of Contents

Advertisement

2-7. Electrical Service Guide

Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil
Reference: 1996 National Electrical Code (NEC)

2-8. Selecting A Location And Connecting Input Power

18 in (457 mm) of
space for airflow
Y Always connect
grounding
conductor first.
= GND/PE
1
Y Do not move or operate unit
where it could tip.
4
L1
L2
2
1
Rating Label
Supply correct input power.
2
Plug
3
Receptacle
Connect plug to receptacle.
4
Line Disconnect Device
See Section 2-7.
Y Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.
3
L1
L2
230 VAC, 1
ssb2.2* 1/94 – ST-801 504
OM-1314 Page 13
230
20.5
25
14
64 (19)
14
S-0092-J