Tig (Gtaw) Cable Connections; Remote 14 Receptacle Rc8 Information - Miller Electric Dimension 652 Owner's Manual

Arc welding power source
Hide thumbs Also See for Dimension 652:
Table of Contents

Advertisement

.
A complete Parts List is available at www.MillerWelds.com

4-13. TIG (GTAW) Cable Connections

!
Turn Off power before making connections.
.
For better performance for most GTAW applications, it is
recommended that electrode negative (DCEN) weld output
connections be made to the high Inductance weld output ter-
minal. Make connections as shown.

4-14. Remote 14 Receptacle RC8 Information

24 VOLTS AC
24 VOLTS AC
REMOTE OUTPUT CONTROL
115 VOLTS AC
115 VOLTS AC
GND
REMOTE POWER ON/OFF
REMOTE POWER ON/OFF
REMOTE VOLTAGE SENSING
REMOTE VOLTAGE SENSING
* Not Used
OM-278 Page 18
HIGH
INDUCTANCE
+
+
Socket
A
24 volts ac. Protected by supplementary protector CB2.
B
Contact closure to A completes 24 volts ac contactor control circuit.
C
Command reference; 0 to +10 volts dc (CC), +10 volts dc (CV).
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from remote control.
F
Current feedback; 1 volt per 100 amperes.
H
Voltage feedback; 1 volt per 10 arc volts.
I
115 volts, 15 amperes, 60 Hz ac. Protected by supplementary protector CB1.
J
Contact closure to I completes 115 volts ac contactor control circuit.
K
Chassis common.
G
Circuit common for 24 and 115 volts ac circuits.
*
To remote On/Off switch.
To remote On/Off switch
*
*
Voltage sensing signal from Negative (−) weld output terminal.
*
Voltage sensing signal from Positive (+) weld output terminal.
Gas Flowmeter/
Regulator
Optional HF Unit
Information

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dimension 812

Table of Contents