Section 5 − Installation; Installing Welding Generator - Miller Electric Big Blue 300 P Owner's Manual

Engine driven welding generator
Hide thumbs Also See for Big Blue 300 P:
Table of Contents

Advertisement

5-1. Installing Welding Generator

Movement
Location/Airflow Clearance
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
Grounding
1
GND/PE
OM-4433 Page 16
SECTION 5 − INSTALLATION
OR
OR
18 in
(460 mm)
18 in
(460 mm)
2
Electrically bond generator frame to
vehicle frame by metal-to-metal contact.
3
Y Bed liners, shipping skids, and some running
gears insulate the welding generator from the
vehicle frame. Always connect a ground wire
from the generator equipment grounding termi-
nal to bare metal on the vehicle frame as shown.
Y Always securely fasten weld-
Y Always
Y If unit does not have GFCI re-
Y Do not install unit where air
.
.
Grounding:
1
OR
2
3
Connect cable from equipment
ground terminal to metal vehicle
frame. Use #10 AWG or larger insu-
lated copper wire.
install3 8/06 − Ref. 800 652 / Ref. 800 477-A / 803 274 / 804 712
ing generator onto transport
vehicle or trailer and comply
with all DOT and other applica-
ble codes.
ground
generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
ceptacles, use GFCI-protected
extension cord.
flow is restricted or engine
may overheat.
See Section 4-2 for lifting eye
rating.
See Section 5-2 for mounting
information.
Equipment Grounding Terminal
(On Front Panel)
Grounding Cable (Not Supplied)
Metal Vehicle Frame