Download Print this page
Miele DA 402 Operating And Installation Instructions
Miele DA 402 Operating And Installation Instructions

Miele DA 402 Operating And Installation Instructions

Miele operating and installation instructions ventilation system da 402

Advertisement

Quick Links

Operating and Installation
Instructions
Ventilation System
DA 402
UV
To prevent accidents
and machine damage,
read these instructions
installation or use.
M.-Nr. 06 473 980

Advertisement

loading

Summary of Contents for Miele DA 402

  • Page 1 Operating and Installation Instructions Ventilation System DA 402 To prevent accidents and machine damage, read these instructions installation or use. M.-Nr. 06 473 980...
  • Page 2: Table Of Contents

    Turning on the fan ..........10 Selecting the power level.
  • Page 3 This appliance is intended for residential use only. Use the appliance only for its intended purpose. The manufacturer cannot be held responsible for damages caused by improper use of the hood. This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage.
  • Page 4 However, under certain conditions it may be possible for installation in these applications. Please contact the nearest Miele dealer or the Technical Service Department with specific requirements. Before servicing or cleaning the unit, switch power off at the service...
  • Page 5 Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings. Always turn the hood on when cooking at high heat or when cooking flaming foods. Clean ventilation fans frequently. Grease should not be allowed to accumulate on the fan or filter.
  • Page 6 When installing the hood, follow the recommended minimum safety distances between a Miele cooktop and the hood: – 22" (55 cm) above electric cooktops, – 26" (65 cm) above gas cooktops, – 26" (65 cm) above an open grill. If local building codes require a greater safety distance, follow their requirement.
  • Page 7 The ventilation hood works by air extraction. The air is drawn in and cleaned by the grease filters and directed outside. The hood comes equipped with a . This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur.
  • Page 8 5 15 – –...
  • Page 9: Delayed Shut Down

    This button turns the light on and off and also dims the light. The lighting can be used independently from the fan. Four fan speed selection This button activates the Delayed Shut Down feature. The fan can be set to turn off automatically after either 5 or 15 minutes.
  • Page 10 ^ Press the On/Off button. ^ Use the " / " controls to select the desired power level. & = increases the fan speed $ = decreases the fan speed Level "1" to "3" (green indicators) are usually sufficient for normal cooking. Level "4"...
  • Page 11 If the power level indicators flash the automatic switch back is not activated. ^ To activate the automatic switch press the " " button. The power level indicators light. ^ To deactivate the automatic switch press the " " button. ^ To save the setting press the Delay Shut down button.
  • Page 12 If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes. ^ Press the Delayed Shut Down button while the fan is still running.
  • Page 13 The overhead lighting can be turned on and off independently from the fan. ^ Press the light button on the lighting. The light button indicator illuminates. ^ Press the light button turn off the lighting. The light button indicator will go out. The brightness of the lighting can be adjusted.
  • Page 14 A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation. The grease filters must then be cleaned. After the grease filters have been cleaned and put in place, the grease filter timer must be reset.
  • Page 15 The grease filter timer is preset to 30 hours. This time can be lengthened or shortened to 20, 30, 40, or 50 hours. – A time of 20 hours should be programmed in kitchens with frequent pan or deep frying. –...
  • Page 16 Before cleaning or servicing the hood, disconnect it from the power supply by either removing the fuse, unplugging it from the outlet, or manually "tripping" the circuit breaker. Warning: Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood.
  • Page 17 The reusable metal grease filters remove solid particles from the vented kitchen air (grease, dust, etc). The grease filters should be cleaned every 3 - 4 weeks or when the grease filter indicator lights. A dirty filter is a fire hazard. ^ To remove the grease filters pull the locking clips, , forward.
  • Page 18: Changing The Light Bulb

    Before changing the light bulbs, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit breaker. When in use halogen bulbs become extremely hot, and they can burn your hands. Do not attempt to change the bulbs until they have had sufficient time to cool.
  • Page 19 In the event of a fault which you cannot correct yourself please contact the Miele Technical Service Department : 1-800-999-1360 techserv@mieleusa.com 1-800-565-6435 service@miele.ca When contacting the Technical Service Department, please quote the model and serial number of your appliance. These are shown on the data plate which is visible when the grease filter is removed.
  • Page 21: Installation Instructions

    Installation Instructions...
  • Page 23 The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. To prevent suffocation of children, ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of their reach. Old appliances may contain materials that can be recycled.
  • Page 25: Dismantling

    scratches to the chimney during installation. for securing the ducting. (125 mm) exhaust ducting. secures the chimney extension Caution: During the installation process, please be careful of sharp edges. to prevent for securing the retaining plates and the canopy. for use with 5" (S8 wall anchors included in the packaging are not for use in USA / CDN.) motor assembly.
  • Page 26 The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing If studs are not available in the required locations, a plywood backing (min. "...
  • Page 27 If there is any question concerning the electrical connection of this appliance to your power supply, please consult a licensed electrician or call Miele’s Technical Service Department. 1-800-999-1360 1-800-565-6435 The hood comes equipped with a 5 ft (1.5 m) power cord with a NEMA 5-15...
  • Page 28 1) and 2) Installation area Wall/ceiling area respectively for vent hole and outlet installation. Vent hole 5 " (150 mm) with reducing collar 5" (125 mm).
  • Page 29 When installing the hood, make sure that the following ( ) between the top of a Miele cooking surface and the bottom of the hood is: - 22" (55 cm) above electric cooktops - 26" (65 cm) above gas cooktops - 26"...
  • Page 30 See the enclosed installation instruction sheet. Please read the "Important Safety Instructions" and Installation instructions before installing this hood. The casing is covered with a protective film to prevent scratching during transport. Peel off the film before installing the casing parts. If the hood needs to be disassembled, follow the instructions on the installation sheet in the reverse order.
  • Page 31 " per foot (1 cm per meter) to prevent condensation from dripping into the appliance. – If the exhaust is ducted through an outside wall, a Miele Telescopic Wall Vent can be used.
  • Page 32: Condensate Trap

    If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney, dryer vent, vent flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.
  • Page 36 Alteration rights reserved / 0805 M.-Nr. 06 473 980 / 00...