Always observe Industry Best Practices when handling, installing, and using this product. This guide is designed for use by trained and certified solar professionals only. BenQ Solar does not assume responsibility for loss, damage or expense resulting from installation, handling or use of this product.
In addition to the applicable rules and regulations, please follow all guidelines for safe handling and/or installation of BenQ Solar modules. In addition to the guidelines below, always observe industry best practices when handling and/or installing any BenQ Solar module. Save this Installation Guide for future reference.
Page 5
Please use caution when handling any module. Please use caution when handling any module. Please use caution when handling any module. Please use caution when handling any module. Remove all metallic jewelry prior to installing this product to reduce the chance of accidental exposure to live circuits.
BenQ Solar Module Specifications The module electrical ratings are measured under Standard Test Conditions (STC) of 1000W/m2 irradiance with AM 1.5G spectrum and a cell temperature of 25ºC. BenQ Solar modules electrical characteristics depend on module Series and Wattage. Please refer to the tables below to learn more about the characteristics of your module(s).
2.3 PM250M01 Series Module Dimensions (L x W x H): 1639 x 983 x 40 mm (64.52 x 38.7 x 1.57 in) Module Dimensions (L x W x H): Module Dimensions (L x W x H): Module Dimensions (L x W x H): Module Weight: Module Weight: 18.5 kg (41.1 lbs) Module Weight:...
2.6 Performance of PV Modules A PV module may produce more current and/or voltage than reported at STC. Sunny, cool weather and reflection from snow or water can increase current and power output. Therefore, the values of Isc and Voc shown below should be multiplied by a factor of 1.25 when determining component voltage ratings, conductor capacities, fuse sizes, and size of controls connected to PV output.
• A torque wrench must be used for assembly. In the examples shown, the tightening torque must be 20N.m. • Refer to product datasheet for the module dimensions and mounting hole locations. PM200M00 / PM245P00 / PM250M01 / PM300P00 PM200M00 / PM245P00 / PM250M01 / PM300P00 PM200M00 / PM245P00 / PM250M01 / PM300P00...
• Measurements of D1, D2, D3, and D4 below describe the centerline of the mounting clamp to the edge of the module frame. • Clips and clamps are not provided by BenQ Solar. • There are two clamping methods available (see below for specific measurements):...
Page 11
Figure Figure 3 3 3 3 Short rail mounting clamp range (D3 and D4) Figure Figure PM200M00 PM200M00 Module PM200M00 PM200M00 Module Module Clamp Location Module Clamp Location Clamp Location Clamp Location Details Details Details Details Long rail Long rail clamping for 5400 Pa design strength: clamp between D1 –...
Chapter Chapter 4 4 4 4 Electrical Installation: Wiring Chapter Chapter Electrical Installation: Wiring Electrical Installation: Wiring and Electrical Installation: Wiring and Grou Grou Grou Grounding nding nding nding 4.1 Wiring DO NOT do any change or adjustment on the cable of Junction Box. DO NOT disconnect cable by yourself! IMPORTANT IMPORTANT...
Page 13
• The cross section for the conductors must be ensured that the voltage drop during the installation does not exceed 2% of its nominal voltage. • BenQ Solar PV modules are supplied with or without cables, according to where they are ordered. Should they be supplied without cables, it is recommended that cables with cross sections between 4 and 10 mm2 be used.
/PM300P00 /PM300P00 /PM300P00 BenQ Solar PV modules have a clearly marked grounding hole on each side of the frame for inserting the ground contact. The grounding screw and bolt are separately used from the mounting parts of the module. Please make sure the grounding screw removes the anodizing from the surface of the grounding holes, or scratch off the anodizing before the grounding connection is made since the frame is fully insulated by anodizing.
PM318B00/ PM318 PM318 For optimal performance, BenQ Solar modules must only be used in configurations with galvanically insulated inverters where the positive (+) polarity of the PV array is connected to ground protected by a fuse. In addition, the module frame should be grounded. Failure to comply with this requirement...
Page 16
BenQ Solar recommends the PV conductor, which cross section is 4 mm2. External connection boxes can be used to enable greater cable cross section area for long distance transmission. The modules are qualified for the application class A: Hazardous voltage (IEC 61730: higher than 50V;...
BenQ Solar PV modules can withstand snow pressure of 2400 Pa.(UL 1703) Please use soft brush lightly removing snow pileup. Do not try to remove frozen snow and solid ice on the module (it will eventually melt off).
Do not leave stagnant water on glass surface. 5.3 Cleaning the Frame BenQ Solar module frames include an anodic oxide coating to increase produce life. The cleaning cycle for regular anodic oxide coatings is generally every six months.
Page 19
Check the tightness and condition of the connection cable junctions. Check the junction box sealing. Should sealing faults be observed, the items which have been affected should be replaced and cleaned. Contact BenQ Solar for additional information about resolving faults in module seal.
Chapter 6 Certification 6.1 IEC Certification The PV modules provided by BenQ Solar all pass the design qualification and type approval standard IEC 61215 edition 2. The PV modules provided by BenQ Solar all pass the safety qualification standard IEC 61730 certified for application class A.