Model
System Type
Power Supply
Rated Current Cooling
Rated Current Heating
System Performance
Cooling Cap (Min/Max)
Heating Cap (Min/Max)
Operating Range - Cooing
Operating Range - Heating
System Specifications
Compressor Type
Sound Pressure - Outdoor
Net/Gross Weight Indoor
Net/Gross Weight Outdoor
Condenser Coil Type
Refrigerant/Charge
Line Set Size Liq. - Suction
Pre-Charged Lineset Ft.
Additional Refrigerant
charge/additional feet
Max. Total Piping Length
Max. Elevation
MCA
MOCP/Breaker Size
Wire Size to Outdoor Unit, #
of Wires per Local Code
Wire Size and # of
Conductors from Indoor to
Outdoor unit
*Comply with National Electric Code or Local Electric Code in selecting proper wire and circuit breaker
size. National Code or Local Code, should supersede wire sizes above.
Note: The manufacturer reserves the right to modify the design and/or change the specifications without notice. Please
refer to specific installation manual for current information.
Physical & Electrical Data, cont.
Amps
Amps
Btu/h
Btu/h
deg F
deg F
dBA
lb
lb
oz
Feet
oz
Feet
Feet
Amps
Amps
awg
RIO18HP230V1A
Heat Pump
208-230v / 60Hz
7.9
11.8
18,000 (4,500-21,000)
19,200 (4,000-23000)
5 - 109
5 - 75
DC Inverter-driven Twin Rotary
56
27/35
106 / 117
R410a / 45.9
1/4" - 1/2"
25
0.2
82
33
15
25
14*
14awg/4c*
RIO24HP230V1A
208-230V / 60Hz
11.5
13.0
22,000 (6,400-24,000)
24,200 (4,100-26,600)
5 - 109
19 - 75
53
33/44
115 / 126
R410a / 54.7
1/4" - 1/2"
25
0.2
82
33
17
25
14*
7