Installation Instructions - Miele KM 88-2 Operating Instructions Manual

Miele electric grill user manual
Hide thumbs Also See for KM 88-2:
Table of Contents

Advertisement

Installation instructions

Installation instructions
This appliance is classified as "Y" class
for heat protection. There may be a wall
at the rear and a wall or tall cabinet at
one side. On the other side, however,
no cabinet or wall must stand higher
than the grill.
There must be a minimum distance
of 9-7/8" (250 mm) between the ap-
pliance and adjacent cabinetry, be-
cause of the heat radiated from the
elements.
2-3/16"
19-5/16"
Prepare the countertop cut-out as il-
lustrated.
Dimension "B" will vary depending on
how many combisets are installed.
The following chart gives dimension
"B" for a variety of 2 zone (ie KM 88-2)
and 4 zone (ie KM 93-2) combinations.
16
2-3/16"'
2 zone Combiset
1 Combiset
2 Combisets
3 Combisets
4 Combisets
5 Combisets
4 zone Combiset
1 Combiset
2 Combisets
3 Combisets
Combination
One 2 zone
+ one 4 zone
Two 2 zone
+ one 4 zone
Three 2 zone
+ one 4 zone
One 2 zone
+ two 4 zone
Two 2 zone
+ two 4 zone
Extractor (e.g. DA 8-2)
For building in between two
appliances:
- Dimension B increases by 90 mm.
For building in at the end of a
combination:
- Dimension B increases by 98 mm.
* Width includes provision for V 98 spacer bar
Width *
Depth
(= Dimen-
in
sion B)
mm
in mm
490
265
490
558
490
851
490
1144
490
1437
490
560
490
1143
490
1728
490
851
490
1143
490
1437
490
1436
490
1729
.

Hide quick links:

Advertisement

Table of Contents
loading