Grounding and Bonding

Follows current DIRECTV approved installation methods
Refer to the Standard Professional Installation Guidelines (SPIG) for more information
Available on the DWS
Visit
http://satinstallinstalltraining.com
Must adhere to all NEC, state and local codes
Whichever more stringent
Use building "house" ground whenever possible
Use a ground block to bond the ODU and D2 Lite enclosure to the
building ground
Ground block must be installed after the ODU and before the D2 Lite
enclosure
Should be located where the best access to a suitable ground location is
Do NOT use an ODU attachment, adjustment screw or bolt as the ground
and/or bond point
Maintain proper bend radius at all times
Follows RG6 bend radius rules
2.75" radius (5.5" diameter)