For Your Safety - Viessmann VITOTRONIC 100 Operating Instructions Manual

Digital boiler control unit
Table of Contents

Advertisement

Introductory information

For your safety

Please follow these safety instructions closely to avoid the risk of injury to persons and damage to property.
If you smell gas
H Don't smoke! Don't use naked
flames or cause sparks (e.g. by
switching lights or electrical ap
pliances on and off)
H Open windows and doors
H Close the gas shut-off valve
H Inform your heating engineers/ser
vice contractors from outside the
building
H Observe the safety regulations of
your gas supply company (see gas
meter) and those of your heating
engineers (see start-up or instruc
tion report).
In emergencies
H Immediately switch off the mains
voltage, e.g. at the separate fuse or
mains electrical isolator switch (un
less there is a smell of gas).
H Close the shut-off valves in the oil
pipes or close the gas shut-off
valve, whichever applicable.
H Use suitable extinguishers in the
event of fire.
Notes on applicability
2
5592391G - page 2 (Black)
Screen angle and frequency: 45.0000, <default>
Work on the equipment
Installation, initial start-up, mainte
nance and repairs must be carried out
by a competent person (heating
engineer/service contractor) as per EN
50 110, Part 1, and VDE 1000, Part 10
(GB: registered with C.O.R.G.I.).
Before work is undertaken on the
equipment/heating system, switch off
the mains voltage (e.g. at the separate
fuse or mains electrical isolator switch)
and take steps to prevent it from being
switched on again.
Gas-fired systems: Also close the gas
shut-off valve and make secure to pre
vent unauthorized use.
Installation of additional components
The installation of additional compo
nents which have not been tested to
gether with the boiler can adversely
affect the function and performance
of the boiler.
Our warranty does not cover and we
accept no liability for damage at
tributable to the installation of such
components.
The Vitotronic 100, Type GC1, can be used in
H single-boiler systems,
H multi-boiler systems in conjunction with Vitotronic 333, Type MW1 and
MW1S,
or
H multi-boiler systems with an external master control.
Multi-boiler system with external master control
Multi-
Please observe the instructions marked by this header in this docu
boiler
ment as well the instructions for the external master control.
system
Multi-boiler system in conjunction with Vitotronic 333, Type MW1 or
MW1S
For this system type you need only consult the operating
instructions for the Vitotronic 333. These contain all the
operating steps for the Vitotronic 100, Type GC1, too.
Boiler room conditions
H Do not use a room in which the air
is polluted by halogenated hydro
carbons (e.g. as contained in aero
sols, paints, solvents and cleaning
agents)
H Do not use a room subject to high
levels of dust
H Do not use a room subject to perma
nently high humidity
H The room should be frost-pro
tected
H Max. ambient temperature 35 °C.
H Provide good ventilation and do
not close or obstruct vents (if in
stalled).
This symbol indicates a ref
erence to other instructions
which must be observed.
This header denotes special
Multi-
instructions which apply to
boiler
the use of the Vitotronic 100
system
in a multi-boiler system.