Metrologic SP5500 OptimusS Series User Manual page 14

Portable data terminals
Hide thumbs Also See for SP5500 OptimusS Series:
Table of Contents

Advertisement

Installation
Settings
S
ETTING
Clock
Backlight ON Period
CPU Speed
Powering Off the Terminal
Power On Options
Key Click
System Password
Tests
The OptimusS has numerous tests available to the user for both operation and diagnostics. Depending
on the application program that is in the active memory will determine which tests can be performed and
are available to the user. The following table provides a description of the available tests.
S
ETTING
Reader
Buzzer
LCD & LED
Keyboard
Memory
Set date and time for the system.
Set the duration for the keyboard/LCD backlight
Set CPU running speed. There are five speeds available:
Full speed, half speed, quarter speed, eighth speed and
sixteenth speed.
Set time threshold for automatically power off when no
operation is taking place during that specified period. If this
value is set to zero, this function will be disabled.
There are two possible selections: Program Resume, which
starts from the program being used during the last session
before the last power-off; and Program Restart, which starts
with a new program.
Select a tone for the beeper or disable the beeper when the
user presses a key button.
Set a password to protect the user from entering the system
menu.
D
ESCRIPTION
To test the reading performance of the scanner. The following symbologies are enabled for
the Reader test. All other symbologies will need to be enabled via programming.
Default Bar codes: Code 39, Industrial 25, Interleave 25,Codabar, Code 93, Code 128,
UPCE, UPCE with ADDON 2, UPCE with ADDON 5, EAN8, EAN8 with ADDON 2
EAN8 with ADDON 5, EAN13, EAN13 with ADDON 2, EAN13 with ADDON 5
To test the buzzer with different Frequency/Duration. Press ENTER key to start and then
press any key to stop the test.
To test LCD display and LED indicator. Press ENTER key to start and then press any key to
stop the test.
To test the rubber keys. Press a key and the result will be shown on the LCD display. Note
that the FN key should be used in conjunction with numeral keys.
To test the data memory (SRAM). Note after the test, the contents of the memory space will
be wiped out.
Warning: This test erases any data stored in the terminal.
D
ESCRIPTION
13
D
EFAULT
N/A
the light goes off after 20
seconds
Full speed
10 minutes
Program Resume
Enable
t
no password is se
D
EFAULTS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Optimuss seriesSp5502

Table of Contents