Basic Operation; Communication And Data Setup - Metrologic SP5500 OptimusS Series User Manual

Portable data terminals
Hide thumbs Also See for SP5500 OptimusS Series:
Table of Contents

Advertisement

Installation

Basic Operation

In order for the Optimus to operate properly, an application program must be loaded onto the PDT. It is
possible for the Optimus to power up without at active application. On power up if the Optimus has no
application program loaded, then the following Application Program menu options will appear on the
display:
M
O
.
ENU
PTIONS
Download
Activate
Upload
Selecting and successfully completing one of these three menu options will enable the OptimusS to
begin functional operation.
Communication and Data Collection Setup
The OptimusS Series has various ways of communicating with a host device. Depending on the model
of Optimus, it can communicate via RS232, USB, or via a wireless Bluetooth connection. The two
models available are the OptimusS Batch (SP5502) and OptimusS/Bluetooth (SP5535). These two
models have various ways of data collection as well. Depending on the model it may store the data on
the terminal itself or transmit live data back to a host device.
The SP5502 stores data in the unit and has the ability to utilize a RS232 or USB connection to
communicate to a host device for both application program downloads and data uploads. The SP5502
includes either a USB or RS232 cable. In order to begin an application download or data transfer the
following steps would need to be followed.
1. Remove the Optimus cradle, the power supply, and either the USB or RS232 cable from the box.
2. Plug the power supply into a power outlet and insert the other end into the cradle. The red LED
on the cradle will illuminate if the power supply is connected correctly.
This option allows the user to download application programs (*.SHX), BASIC run-time
(bas.ops.shx), BASIC programs (*.SYN) or font files to the terminal. There are 6 resident
locations and one Active Memory. A maximum of 7 programs can be downloaded to the
terminal. The application program downloaded to the Active Memory will be the only activate
program running. In order to activate one of the other programs, immediately after
downloading, input a name for the program desired or just press the enter key to keep its
current name if one is applicable. This will enable the user to download the program. The
application program's type, name, and size will be shown on the list of programs when
entering the Download or Activate menu of the Program Manager. The file type is a small
letter that follows the program number (01~06), it can be either 'b', 'c' or 'f' which represents
BASIC program, C program or font file respectively. The program name is up to 12
characters and the program size is in units of K bytes.
NOTE: In order to delete a program, select the program designated for deletion. From the
program information screen, press the Alpha/Function key, then zero.
This option will enable the use to activate one of the resident programs. In order to
accomplish this, the user must copy one of the 6 resident programs to the Active Memory.
Upon activation of the new program the original program in the Active Memory will be
replaced. Note: A font file cannot be activated, and a BASIC program cannot be activated if
the BASIC run-time does not exist.
The Upload option gives the user additional method for retrieving an application program. It
allows a user to transmit the application programs to a host PC or another terminal. This
function also allows a terminal to be cloned without going through a PC.