USER MANUAL
CASSETTE FAN COILS
SF-08C, SF-12C,SF-16C

Advertisement

Table of Contents
loading

Summary of Contents for Sinclair SF-12C

  • Page 1 USER MANUAL CASSETTE FAN COILS SF-08C, SF-12C,SF-16C...
  • Page 2  ...
  • Page 3: Table Of Contents

    CONTENTS 1. Safety cautions ...................1 2. Names and functions of parts .............1 3. Operation of remote control .............2 3.1 Guide for operation-general operation ..........5 3.2 Guide for operation-optional operation ...........5 3.3 Introduction for special function .............5 3.4 Changing batteries and notices ............6 4.
  • Page 4: Safety Cautions

    Cassette Type Fan Coil Unit Owner`s Manual 1. Safety cautions Read the following carefully to assure safe use. Warning ♦ Avoid direct air flow to your body and avoid excessive heating or cooling, which may make you feel uncomfortable and do harm to your health. ♦...
  • Page 5: Operation Of Remote Control

    Cassette Type Fan Coil Unit Owner's Manual in the heat-exchanger and the air flowing through the surface of the one, so that, the demand of the air condition is attained. This production is only an indoor unit, the running mode is decided by the temperature of the environment and the running mode of the water system.
  • Page 6 Cassette Type Fan Coil Unit Owner`s Manual...
  • Page 7 Cassette Type Fan Coil Unit Owner's Manual...
  • Page 8: Guide For Operation-General Operation

    Cassette Type Fan Coil Unit Owner`s Manual 3.1 Guide for operation-general operation P ress ON/OFF button to start the unit after poweringthe ① . main unit on.(Note: Power the unit on every time,the big-guide louver and small-guide louver will beclosed firstly.) P ress MODE button to select desired running mode.
  • Page 9: Changing Batteries And Notices

    Cassette Type Fan Coil Unit Owner's Manual status, If turn off the unit by remote controller, the unit will not stop defrosting until it is finished; if change setting mode by remote controller, the function ,which is set last time, won't be carried out until defrosting finished.
  • Page 10: Trouble Shooting

    Cassette Type Fan Coil Unit Owner`s Manual 4. Trouble shooting Warning ♦ In case of something abnormal(such as bad smell), shut the power switch immediately and contact service center. Do not repair the air conditioner by yourself, because wrong repair may cause fire, please contact service to do it for you.
  • Page 11: Installation Accessories

    Cassette Type Fan Coil Unit Owner's Manual ♦ The following are not troubles Trouble Cause Restart right after stopping Once the unit is turned off, it will not operate for about 3 minutes to protect The unit does not Press SET TEMP. and then release operate.
  • Page 12: Selection The Mounting Position

    Cassette Type Fan Coil Unit Owner`s Manual Heat reservation Encase the tie-in sponge for pipe Big sealing pad 5×160×300 Sealing pad 5×45×300 Small sealing pad 5×30×150 Sealing bar 120×65×25 PVC tape 30×10 Screws ST4.2×9.5PA For mounting the remote Remote controller control Battery AAA1.5V...
  • Page 13: Installation

    Cassette Type Fan Coil Unit Owner's Manual weight of the indoor umt (5). The inlet and outlet ports should not be obstructed; the air should be able to blow all over the room. (6). Leave the space required to service the air conditioner. (7).
  • Page 14: Precoutions For Drainage Raising Pipe

    Cassette Type Fan Coil Unit Owner`s Manual 7.2 Precoutions for drainage raising pipe Install the drainage raising pipe at a height of less than 280mn. Install the drainage raising pipe at a right angle to the indoor unit and no more than 300 mm from the unit.
  • Page 15: Check If Drainage Water Flows Smoothly

    Cassette Type Fan Coil Unit Owner's Manual motorized valve, and lastly connect the motorized valve with the flare nut. During the installation, both the torque wrench and the spanner should be used and the moment of torque should be within 90 N.M.
  • Page 16: Electric Wiring

    Cassette Type Fan Coil Unit Owner`s Manual Warning:Before obtaining access to terminals,all supply circuits must be disconnected. 7.5 Electric wiring (1). All field supplied parts and meterials must conform to local laws and regulations. (2). For electric wiring, refer to “WIRING DIAGRAM” attached to the unit body. (3).
  • Page 17 Cassette Type Fan Coil Unit Owner's Manual (3). Hang the latch, which is located on the opposite side of the swing flap motor on the panel. temporarily to the book of the indoor unit. (2 Positions) (4). Temporarily hang the remaining 2 latches to the hooks on the sides of the indoor unit.(be careful not to let the swing motor lead wire get caught in the sealing material.) (5).
  • Page 18: Test Operation

    Cassette Type Fan Coil Unit Owner`s Manual ♦ If gap is still left between the ceiling and the panel after screwing the screws, readjust height of the indoor unit body. After fixing, be sure no gap left between the ceiling and the panel. ♦...
  • Page 19: Emergency Operation

    Cassette Type Fan Coil Unit Owner's Manual 8.3 Emergency operation. When the batteries fail or when the remote controller is missing, operate as shown below. *On stopping you can press the “AUTO” button on cover NO.II unitl it is in “AUTO” mode. The air conditioner select from COOL,HEAT,FAN modes automatically.
  • Page 20 185/2001 Coll., in the wording of later regulations. In case of incorrect disposal of this waste, a fine can be imposed according to national regulations. Manufacturer: Sinclair Corporation Ltd., 1-4 Argyll Street, London W1F 7LD, UK Supplier and technical support: Nepa, spol.s.r.o.

This manual is also suitable for:

Sf-08cSf-16c