• When mounting 2 or more units in an equipment rack, be sure to mount a perforated panel larger than 1U
size above every 2 stacks of amplifiers as shown in the figure.
*1U size = 44.5 mm (standard size)
VP-1241 or
VP-1361
VP-1061 or
VP-1121
• It is recommended that a supporting runner be installed to the rack so that the unit can be easily drawn from
the front of the rack for maintenance purpose.
For the installation procedures of the supporting runner, please contact manufacturer for the rack to be used.

8. REMOVABLE TERMINAL PLUG CONNECTION

Note
• Avoid soldering cable conductor, as contact resistance may increase when the cable is tightened and the
solder is crushed, possibly resulting in an excessive rise in joint temperatures.
• Usable cables of AWG 16 - 28.
Cable end treatment
Shielded cable
Connector Connections
Step 1. Loosen the terminal screw, then insert the cable.
Step 2. Retighten the terminal screw.
Note
Pull on the cable lead to ensure it is securely connected.
Tip
Recommended slotted screwdriver: Screwdriver with blade that is 3 mm in width.
Bit shape 3 mm
7 mm
20 mm
Perforated panel
2
Tightens
1
Hot
Earth
Cold
Shielded cable
Slotted screwdriver
1
Loosens
Terminal screw
Removable terminal
plug