5.1.2.

Sensor disconnection mode

• When the disconnection of a sensor is detected, all load of
the device goes off in this mode.
Load control
• LED indication: Flashes on and off, and it is displayed "H 02"
by the clock part.
• LCD indication: Turn off the light.
• Buzzer information: OFF
• Heater: OFF
• Motor: OFF
5.1.3.
Sensor disconnection mode
• When the disconnection of a sensor is detected, all load of
the device goes off in this mode.
Load control
• LED indication: Flashes on and off, and it is displayed "H 01"
by the clock part.
• LCD indication: Turn off the light.
• Buzzer information: OFF
• Heater: OFF
• YD / RD: OFF
• Room temperature sensor(TH1) detection temperature
except the disconnection when is in a condition, it is with
"wait mode - function choice - fault choice".
At this time, I display "H01" if a sensor is snapped.
Indication on LCD
• "H02" is displayed on the LCD during the sensor disconnec-
tion. ("H02" is brinking)
• Motor: OFF
• YD / RD: OFF
• Sensor detection temperature except the disconnection
when is in a condition, it is with "wait mode - function choice
- fault choice".
Indication on LCD
• "H01" is displayed on the LCD during the sensor disconnec-
tion. ("H01" is brinking)
17