Mitsubishi Electric PEH-2.5EAK Installation Manual page 9

Hide thumbs Also See for PEH-2.5EAK:

Advertisement

Available languages

Available languages

. Electrical work
SW500:
Fig. 6-10
SW501:
Refrigerant address 0
Refrigerant address 1
Refrigerant address 15
Fig. -11
Fig. -1
SW501
SW No
No.1
No.2
No.3
No.4
SW501
SW No.
No.5
Room temperature detector
No.6
Whether or not Mr. Slim is present in the group.
Refrigerant address 2
Refrigerant address
Refrigerant
address 0
Refrigerant
address 1
Refrigerant
address 2
Refrigerant
address 3
Refrigerant
address 4
Refrigerant
address 5
Refrigerant
address 6
Refrigerant
address 7
Function
Indoor unit
Mr. Slim absent
..1 Dip switch settings
SW500: (Fig. 6-10)
Does not have to be set (Set OFF of all switch)
SW501:
• SW501-No.1~4:Refrigerant address (Fig. 6-11)
*Always start the refrigerant address at "0".
• SW501-No.5, 6 (Fig. 6-12)
No.5:Set OFF
* Room temperature detector
ON:MA remote controller
OFF:Indoor unit
On this model, the MA remote controller does not detect temperatures when the
interface is connected.
No.6:Set ON
* Whether or not Mr. Slim is present in the group
ON: Mr. Slim present
OFF: Mr. Slim absent
Refrigerant
address 8
Refrigerant
address 9
Refrigerant
address 10
Refrigerant
address 11
These setting when connecting an MA remote controller
Refrigerant
address 12
Refrigerant
address 13
Refrigerant
address 14
Refrigerant
address 15
OFF
ON
MA remote controller *No function
Mr. Slim present
Table 1
Comments
(PAR-21MAA)
Table 2
Comments
Be sure to set it OFF
Be sure to set it ON
9