Adjust lens position (0°, -5° or -10°) according to desired maximum
sensor range (see table below).
Remark: Do not use positions +5° or +10° as they do not apply to
this PIR.
Sensor height
2.5 m
2.0 m
1.5 m
7. Make the interconnections between the PIR and the alarm/action
box with the cable supplied (see figure below).
4
3
7
1
Terminal block (for interconnection with alarm/action box)
2
Lens position (sensor range adjustment)
3
Jumper (walk test LED activated/deactivated)
4
Tamper switch
5
PYRO sensor
6
Jumper (1, 2 or 3 pulse count)
7
Locking latch
8
Terminal block in alarm/action box
Bosch Security Systems | 2004-06
Maximum sensor range (m) / Lens position (°)
14 m
12 m
10 m
2
1
NC
GND
+12V
6
5
-5°
12.5 m
10.5 m
8.5 m
8
EN | 9
-10°
11 m
9.5 m
8 m