M
aintenance and care
Check rotating floor brush
& drive belt (cont)
5. Clean strings, hair and other debris
from rotating floor brush, paying
particular attention to brush ends.
6. Clean strings, hair and other debris
from motor pulley and drive belt areas.
7. Check drive belt carefully for wear,
cuts or stressed areas. Replace if worn.
8. Check air passageway for obstruc-
tions. Remove debris from this area.
Replace drive belt
Use only BISSELL Style 7 Replacement Belts
(#32074) in your BISSELL Pro PowerForce.
1. Unplug cleaner from electrical outlet.
2. With rotating floor brush removed from
vacuum cleaner (Steps 1-4 of Check
rotating floor brush and drive belt),
grasp old drive belt and remove from
motor pulley. Discard old drive belt.
3. Place new drive belt over motor pulley
and stretch other end over rotating floor
brush in the space between the bristles.
4. Place ends of rotating floor brush
down into slots on sides as shown.
5. Turn rotating floor brush by hand
several times in direction of motor
pulley. If properly installed, drive
belt will center itself.
6. Reposition brush cover and four
screws. Tighten screws securely.
Make sure end of brush cover is
snapped into place.
w w w . b i s s e l l c o m m e r c i a l . c o m
Motor Pulley
Press here
8 0 0 . 2 4 2 . 1 3 7 8
Air
Passageway
Brush
Cover
11