3. The appliance must be isolated from the gas supply piping
system by closing its individual manual gas shutoff valve (not
supplied with heater) during any pressure testing at pressures
in excess of ½ Psig (3.5 kPa).
The appliance and its gas connection must be leak tested
before placing the appliance in operation.
4. Keep water heater area clear and free from combustibles
and flammable liquids. Do not locate the heater over any
material which might burn.
5. Correct gas pressure is critical for the optimum operation of
this heater. Gas piping must be sized to provide the required
pressure at the maximum output of the heater, while all the
other gas appliances are in operation. Check with your local gas
supplier, and see chapter 3.6 and 3.7 to verify proper gas line
sizing.
6. Should overheating occur or the gas supply fail to shut off,
turn off the gas supply at the manual gas shut off valve, on the
gas line. Note: manual gas shutoff valve is not supplied with the
heater.
7. Do not use this appliance if any part has been underwater.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and any
gas control which has been underwater.