Vaillant ecoTEC plus Installation And Maintenance Instructions Manual page 63

Table of Contents

Advertisement

Technical data – Electrics
Electric connection
Permissible connected
voltage
Built-in fuse (slow-blow)
Min. electrical power con-
sumption
Max. electrical power
consumption
Standby electrical power
consumption
Level of protection
Test symbol/registration
no.
0020209593_01 ecoTEC plus Installation and maintenance instructions
938 (VUI GB
386/5‑5 A)
ecoTEC plus
230 V/50 Hz
190 ... 253 V
2 A
55 W
140 W
2.7 W
VUW
2.0 W
VIHCL
IP X4 D
CE‑
0085CM0320
Appendix