3-2-1 THERMOSTAT
OFF :
When the room temperature is lowered by the air
conditioner, the gas within the thermostat will
contract and cause a break in the electric
contact. The compressor will then stop.
After the compressor stops, the room
temperature will rise
ON :
As the room temperature increases to a
selected level, the gas within the thermostat
expands, causing electric contact, which
provides the source of electric power to the
compressor. The room temperature will fall
and the cycle will repeat.
3-2-2 Operation
The fan selector switch offers high and low fan cooling control levels to assure maximum comfort.
The two fan speeds allow you to economically circulate room air flow on days when intense cooling is
not required. When combined with the thermostat(set to call for conditioned air), these controls cool,
dehumidify, filter, and circulate room air, with the fan continuing to circulate air even when the
compressor is turned off.
3-2-3 Timer control
The timer enables the air conditioner to operate for a specified period of time, and then turns off auto-
matically while the user is sleeping, shopping, etc.. To use this function, set the ti to the desired time, and
the air conditioner will automatically shut itself off after running for the selected period ot timer.
Utility bills can be reduced and comfortable temperatures maintained with the use of the timer.
For continuous operation, set the timer control to "continue".
3-2-4 Air swing switch
• On (
) : Automatic oscillation distributes the air flow throughout the room.
(controls left the right and left blade-V.)
• Off (
) : Maintains a fixed direction of air flow, Set the Air switch to OFF at the instant the wave fins
come to the desired position.
Samsung Electronics
Installation and Operating Instructions
Control Operation :
By turning the control knob clockwise(toward
higher numbers), the temperatures will be cooler.
By turning the control knob counterclockwise
(toward lower numbers), the temperature will be
warmer.
Level 1 : Cool air will be supplied above 30~35°
Level 1 :
Cool air will be ceased below 28~32.5°
Level 10 : Cool air will be supplied above 17.4~20.4°
Level 1 :
Cool air will be ceased below 14.4~17.4°
3-3