5-2 Trouble check in the initial status
5-2-1 Diagnosis and marking of the part in trouble.
Please check the air conditioner operation status and write the check result in the chart in the room.
Description
Indoor unit room temperature sensor error
(open or short)
Indoor unit heat exchanger temperature sensor error
(open or short)
Indoor fan motor mal function
EEPROM error
Option error
(option wasn't set up or option data error)
5-2-2 Operation with abnormal motion
No
Abnormal condition
1
No response from
the remote control
operation signal.
2
Unable to operate the
outdoor unit
Samsung Electronics
Inspection
• Plug out and plug in 5 seconds later.
• Press the TURBO button with the
remote control.
• In 3 minutes, check the voltage
between the indoor unit terminal
block N(1) and 1.
LAMP
OPERATION
TIMER
Able to operate the
remote control.
Unable to operate
Press the
the remote control.
• If it operates, the remote control and
• If not, the indoor unit is in trouble.
AC200V ~ AC240V
Problem with the outdoor unit or PCB
No power source
Problem with the relay (RY71) or PCB
displayed.
TURBO
: Lamp off
: Lamp flickering
Initial Diagnosis
OK
button in the indoor unit.
indoor unit receiver are in trouble.