3.2 INSTALLATION

We strongly recommend the removal of the
old wall sleeve and the installation of a new
FRIEDRICH USC Wall Sleeve.
If you decide to keep the existing wall sleeve,
you have to redirect the louvers at the back of
the wall sleeve illustration. The use of pliers is
recommended. If you DO NOT redirect, you run
the risk of poor performance or product failure.
This is not covered under the terms of the
FRIEDRICH warranty.
• Pick a location which will allow the conditioned air to
blow into the area you want. Good installation with
special attention to the proper position of the unit will
lessen the chance that service will be needed.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts in the kit. Discard unused
parts
ITEM (inches)
Plastic grille
Horizontal Insulation Strips
Around Insulation Strips
Support Block
Baffle
Shim
Trim Frame
Washer Screw
Nuts(Plastic)
HOW TO INSTALL
1
Identify the existing wall sleeve before installing the unit
from the listed below.
Brand
White-Westinghouse
Frigidaire
Carrier (52F series)
General Electric
/Hotpoint
Whirlpool
Fedders/Emerson
Friedrich WSC
FRIEDRICH USC
Emerson/Fedders
Carrier (51S Series)
CAUTION
26
3 / 4
x 16
1 / 2
3 /
5 /
3 /
1
x
x 27
8
8
16
1
3 / 8
x 1
3 / 8
x 27
3 / 16
1
3 /
x
3 /
x 61
1 /
8
4
2
3 /
3 /
1 /
1
x 1
x 61
8
8
2
3 / 4
3 / 8
5 / 16
1
x 1
x 4
14 x 4
1 /
x
1 /
2
8
13 x 1 x
3 / 4
Wall Sleeve Dimensions (inches)
Width
Height
Depth
16, 17-1/2
25-1/2
15-1/4
26
15-5/8
16-7/8
17-1/8
25-7/8
16-1/2
16-3/4
27
16-3/4
or 19-3/4
25-7/8 15-17/32 16-23/32
26-3/4
15-3/4
25-3/4
16-7/8
18-5/8
NOTE: All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition and
have a rear grille that securely attaches to sleeve, or
rear flange that serves as a stop for the Air
Conditioner.
Remove old air conditioner from existing wall
2
sleeve.
Clean the interior of an existing sleeve.
3
(Do not disturb seals.)
Wall sleeve must be securely fastened in wall
4
before installing the air conditioner. Use the nails
or screws through sleeve into wall, if needed.
Repaint sleeve if needed.
Prepare the wall sleeve for installation of the unit.
5
If you plan to use your existing wall sleeve, and it
is not FRIEDRICH, use procedure B or C below.
Procedure
A
Qty.
B
1
1
1
1
1
C
2
1
2
2
6
Install new unit into wall sleeve.
4
CAUTION: When installation is completed,
4
replacement unit MUST have a rearward slope as
shown.
FRONT
or 22
or 23
15
—16—
Brand
FRIEDRICH USC
White-Westinghouse
Frigidaire Carrier
(52F series)
General Electric
/Hotpoint
Whirlpool
Carrier (51S series)
Fedders/Emerson
Emerson/Fedders
UNIT
Wall Sleeve
1/4"
Depth(inches)
16-23/32
16, 17-1/2
or 22
16-7/8
17-1/8 or 23
18-5/8
16-3/4
or 19-3/4
15
FIG. 20

Hide quick links: