GE APS12DA Use And Care Manual page 5

Heat/cool models

Advertisement

For
Norm.aICooling
1. Set SELE~R
switchat HIGH
COOL.
2. Set THERMOSTATcontrol at
desirednumkr (usuallythe midpoint
is a good starting position). If room
temperatureis not satisfactoryafter
a reasonabletime, setthetemperature
control at a higher number for a
cooler room or at a lower number
for a warmer room.
~0~
Maximum Cooling
1.
Set SELE~OR switch at HIGH
COOL.
2. SetTHERMOSTATcontrolat 10.
3. Set VENTILATION control at
CLOSE position.
4. Shifi ENERGY SAVERswitch
to NORMAL.
For Quieter
Opemtion
1. Set SELE~R
switch at LOW
COOL.
2. Set THERMOSTAT control at
desired number.
3. Set VENTILATION control at
CLOSE position.
4. Shift ENERGY SAVERswitch
to desired position—SAVEor
NORMAL.
LFQF PiiqllttiBme OperatioEl
During the cooler evening hours,
it is recommended that you set the
SELE~R
at LOW COOL for
very quiet operation and the
THERMOSTAT control at mid
range (5 or 6).
For ExtrenRe T@mperatuTes
For greatest economyand best
performance, we suggestyou
alwaysset the SELEC~R at
HIGH COOL in extremelyhot
weather.
For air cireu~ation
and
filtering
withol~t cooling
Set SELE~R
switch at FAN
ONLY.
~For fan onl))operation, ENERW
SAVE. switch must be in NQRM~
position.
For Ventilation
Whethercontrolsare set for cooling,
heathg or fm only operation,setting
VENTILATION control at OPEN
lets room air be efiausted to the
outside. This is helpfu~in removing
stale air, smoke or odors from the
room, and permits outdoor air to
enter through normalopeningsin the
house.However,coolingeffwtiveness
is reduced when this control is set
at OPEN, so we suggestyou don't
keep it there long—especiallyin
hot, humid weather.
For Normal
Heati~
1. Set SELE~R
switch at HIGH
HEAT.
2. Set THERMOSTAT control at
desirednumber (usudy the midpoint
is a good starting position). If room
temperature is not satisfactory after
a reasonabletime, setthe temperature
control at a lower number for a
warmer room or at a higher
number for a cooler room.
For
MaximumHeatiRlg
1. Set SELE~R
switchat HIGfI
HEAT.
2. Set THEWOSTK~ controlat 1.
3. Set VENTILATION control at
CLOSE position.
4. Shift ENERGY SAVERswitch
to NORMAL.
Importint:
when the outdoor temperature
is
lower than 35*F.,
heat is providef~
by the electric heater in the air
conditioner instead of by the heat
pump.
To Adjust Mr Direetion
Up-and-down air direction: Tabs
(A) let you direct discharged air up,
down or straight ahead.
~id~-tO-Sid~ air tirection:
Tab (~)
lets you direct discharged air to the
left, to the right or straight ahead.
Tab B for
side-to-side -
adjustment
u.
.