Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
TURNTABLE MOTOR
Refer to page 4-7 for the procedure for servicing
the turntable motor.
1.
Unplug microwave oven or disconnect
power.
2.
Disconnect the wire connector from the
turntable motor.
3.
Set the ohmmeter to the R x 1K scale.
4.
Touch the ohmmeter test leads to the
turntable motor terminals. The meter
should indicate between 2700 and
3800 Ω.
WARNING
Electrical Shock Hazard
HV CAPACITOR
Refer to page 4-12 for the procedure for servic-
ing the high voltage capacitor.
1.
Unplug microwave oven or disconnect
power.
2.
Discharge the high voltage capacitor
terminals with a 20,000
chassis ground.
3.
Disconnect the wires from the capacitor
terminals.
4.
Set the ohmmeter to the R x 1K scale.
5.
Touch one of the ohmmeter test leads to
the chassis, and the other test lead to each
of the capacitor terminals. The meter
should briefly indicate a low resistance,
and then gradually return towards infinity.
5-2
Ω
resistor to