Electrical Requirements - U.s.a. Only - Maytag W10252706B Installation Instructions Manual

30" (76 cm) freestanding electric ranges
Table of Contents

Advertisement

Product Dimensions
A
F
E
A. 27
" (69.9 cm) max. depth with handle
B. 46 " (119.1 cm) overall height (max.) with leveling legs
screwed all the way in*
C. 36" (91.4 cm) cooktop height (max.) with leveling legs screwed
all the way in*
D. 29 " (75.9 cm) width
E. 25" (63.5 cm) depth
F. Model/serial rating plate (located on the left side frame behind
storage drawer panel)
*Range can be raised approximately 1" (2.5 cm) by adjusting the
leveling legs.
Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm)
countertop depth, 24" (61.0 cm) base cabinet depth and
36" (91.4 cm) countertop height.
IMPORTANT: If installing a range hood or microwave hood
combination above the range, follow the range hood or
microwave hood combination installation instructions for
dimensional clearances above the cooktop surface.
A freestanding range may be installed next to combustible walls
with zero clearance.
4
B
C
D
E
A. 13" (33.0 cm) max. upper cabinet depth
B. 30" (76.2 cm) min. opening width
C. For minimum clearance to top of cooktop, see NOTE*.
D. 30 " (76.5 cm) min. opening width
E. Outlet - 8" (20.3 cm) to 22" (55.9 cm) from either cabinet,
5 " (14.0 cm) max. from floor
F.
" (2.2 cm) min. required between cutout and cabinet door or
hinge.
*NOTE: 24" (61.0 cm) minimum when bottom of wood or metal
cabinet is covered by not less than
millboard covered with not less than No. 28 MSG sheet steel,
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the
cooking platform and the bottom of an uncovered wood or metal
cabinet.

Electrical Requirements - U.S.A. Only

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269.
WARNING: Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check with a
qualified electrician or service technician if you are in doubt as to
whether the appliance is properly grounded. Do not modify the
power supply cord plug. If it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
A
C
B
D
F
" (0.64 cm) flame retardant