Appendix A Error Messages
Message
number
E0208
E0209
E0210
E0211
E0212
E0213
E0214
E0215
E0216
E0300
E0301
E0302
E0303
E0304
E0305
E0306
Competing with deleting Thin Provisioning Volume in background process.
A Thin Provisioning Pool is being deleted by another process. Wait for a while and try again.
Competing with formatting Thin Provisioning Volume in background process.
A Thin Provisioning Pool is being formatted by another process. Wait for a while and try again.
Competing with setting Thin Provisioning Volume parameters in background process.
The Thin Provisioning Pool parameters are being set by another process. Wait for a while and try again.
Competing with registering REC Disk Buffer Volume in background process.
An REC disk buffer volume is being registered by another process. Wait for a while and try again.
Competing with deleting REC Disk Buffer Volume in background process.
An REC disk buffer volume is being deleted by another process. Wait for a while and try again.
Competing with inhibiting copy destination volume in background process.
A copy destination volume is being protected by another process. Wait for a while and try again.
Competing with Thin Provisioning Pool migration in background process.
Thin Provisioning Pool Migration is being performed by another process. Wait for a while and try again.
Competing with setting cache size limit to volume in background process.
The cache size limit is being set by another process. Wait for a while and try again.
Competing with setting Offloaded Data Transfer Mode in background process.
The ODX mode is being set by another process. Wait for a while and try again.
Syntax error in REC path information. (Incorrect file header)
A syntax error was detected in the specified REC path information file. Specifically, the header identifier is
incorrect. Check the output line given in the details of this message and amend the header identifier.
Syntax error in REC path information. (Version mismatch)
A syntax error was detected in the specified REC path information file. Specifically, the version
information is mismatched. Check the output line given in the details of this message and amend the
version information.
Syntax error in REC path information. (Incorrect label)
A syntax error was detected in the specified REC path information file. Specifically, the label name is
incorrect. Check the output line given in the details of this message and amend the label name.
Syntax error in REC path information. (Incorrect operand)
A syntax error was detected in the specified REC path information file. Specifically, the operand name is
incorrect. Check the output line given in the details of this message and amend the operand name.
Syntax error in REC path information. (Duplicate definition)
A syntax error was detected in the specified REC path information file. Specifically, the specified
definitions are duplicated. Check the output line given in the details of this message and amend the
incorrect definition.
Syntax error in REC path information. (Missing label)
A syntax error was detected in the specified REC path information file. Specifically, the required label
names are missing. Check the output line given in the details of this message and add the required label
names.
Syntax error in REC path information. (Too many labels)
A syntax error was detected in the specified REC path information file. Specifically, unnecessary label
names exist. Check the output line given in the details of this message and delete any unnecessary label