Initiate A Phone Session From The Control Panel; Configure Required Control Panel Settings; Walk Test Wireless Devices - Bosch ICP-EZM2 System Reference Manual

Easy series control panel
Hide thumbs Also See for ICP-EZM2:
Table of Contents

Advertisement

Easy Series Control Panel
The upgrade is complete (after 5 to 10 minutes), when the green (√) LED on the control panel
flashes. Remove the green upgrade programming key.
3.5.2

Initiate a Phone Session from the Control Panel

1.
2.
3.
Notice!
For more information on default passcodes, refer to System Access by Phone, page 38.
3.5.3

Configure Required Control Panel Settings

1.
2.
3.5.4

Walk Test Wireless Devices

Device
Motion Detectors
Smoke Detector
Bill Clip
Inertia Detector
Glass Break Detector
Mini Door/Window
Contact
Recessed Door/Window
Contact
Door/Window Contact
To test the inertia detector, create a shock to cause an inertia alarm, and then restore alarm.
1
To test the glass break detector, use a special tool to cause a glass break alarm, and then restore the alarm.
2
If you tamper the detector, the control panel enrolls the detector, but does not test it. You must create the
3
appropriate alarm and restore the alarm to test the detector.
Table 3.3: Wireless Device Test Procedures
Bosch Security Systems, Inc.
Connect a phone set to the test posts or to the phone terminals. Refer to System
Components and Wiring, page 18.
Press and hold the System Test button for approximately 15 sec. Refer to System
Components and Wiring, page 18, figure 2 or the location of the Test button.
When prompted, use the phone set to enter the installer passcode (default is 5432[11])
for the Installer Menu, or the master user passcode (default is 1234[55]) for the User
Menu. For the following two procedures, enter the installer passcode.
From the Installer menu, if prompted to set the control panel date and time, press [1][1].
When finished following the prompts, press [#][#] to return to the Installer Menu.
If prompted to set the Country Code, press [3][4]. Refer to Country Codes, page 111 for
the appropriate Country Code. When finished following the prompts, press [#] to return
to the Installer Menu.
To Test
Walk across the detector's coverage pattern.
Press and release the detector's test button, or blow smoke into the detector's chamber
to cause an alarm. Restore the alarm.
Remove and restore the shim in the gap of the Bill Trap.
Magnetic Switch: Open and then close the magnetic switch.
Inertia Only: Cause an alarm and then restore the alarm
Cause an alarm and then restore the alarm, or tamper the detector.
Open and then close the magnetic switch.
Open and then close the magnetic switch, or fault and then restore the supervised loop.
Perform both tests only if both the magnetic switch and supervised loop are used.
System Reference Guide
System Installation and Configuration | en
, or tamper the detector.
1
3
2014.09 | 01 | F.01U.306.221
33
3