Revision Date Description 17 December 2004 Initial Release of Document Tools Required To install the Series 2000 Treadmill, you will need the following tools: Multi-meter Standard hand-tools Allen wrench (included with treadmill) Carpenter’s level 9/16 or 15 mm Socket wrench...
For proper and safe operation of the treadmill, ensure the power source is clean. Equipment Assembly The Series 2000 Treadmill ships completely assembled except for the handle set and the emergency stop switch. As recommended by the American Heart Association Exercise Standards (Special Report, Vol 82, No 6), the treadmill should have front and side rails installed for patients to steady themselves.
Page 3
7. Attach the side rails to the front rail with the mated T-brackets. Tighten the two T-bracket bolts with the Allen wrench. 8. Make sure all screws and bolts are seated properly and no sharp edges are present. 9. Reassemble the shroud and align the grommets properly. 2021403-028A Series 2000 Treadmill...
3. Connect the cable from the emergency stop switch to the mating connector on the treadmill’s rear connector panel. 4. Use the cord clips to attach the cable along the front handrail and secure the excess cable. Series 2000 Treadmill 2021403-028A...
Safe Handling Guidelines The Series 2000 Treadmill ships preset with an approximate 2% grade. This slight elevation provides for free wheel movement and prevents the shroud from scraping the floor. If you are moving the treadmill after it has been in operation, use the controlling equipment to set the grade to approximately 7%.
4. Make sure all screws on the handles are well secured. Calibration To activate the Series 2000 Treadmill self-calibration feature, do the following: 1. Connect the AC power cable on the treadmill to the wall outlet. WARNING POWER CABLES —...
The software calibrates the speed and grade from the minimum points to the maximum points. 6. Make sure you turn the Series 2000 treadmill power off before you proceed to the next section. Check Treadmill Level...
1. Attach the appropriate controller cable from the stress system or MTC-1 and the AC power cable. Use the supplied interface cable to connect the Series 2000 treadmill to the host (i.e., CASE, MTC-1). Series 2000 Treadmill 2021403-028A...
3. Turn the controlling device power switch ON. Emergency Stop Switch Check 1. Manually control the speed of the Series 2000 Treadmill from the controlling device. With the belt moving at a relatively high speed, press the emergency STOP switch. The treadmill belt will stop promptly but the belt will not lock, allowing for removal of foreign objects.
Contact site electrician to correct. into the outlet? Check Treadmill Level Is the unit level and stable. If unit is not level, adjust. Is the floor under the unit smooth and Relocate treadmill. with no loose tiles? Series 2000 Treadmill 2021403-028A...
Page 11
Can Host control elevation and speed ? (1)Turn on and configure Host system. Turn on Treadmill. At Treadmill power up, listen for treadmill beep. If no beep, tighten interface cable between host and treadmill. (2) Replace Interface cable. (3) Contact Tech Support. 2021403-028A Series 2000 Treadmill...
Before you leave the installation site, recommend to the biomed to perform a complete system leakage test after the Series 2000 Treadmill has been connected to the host device. Refer the biomed to the host device service manual for instructions on performing the appropriate leakage tests.