Guide to diagnostics of NEW COLLECTION EWM09312 electronic controls

Diagnostic test phases

Irrespective of the type of circuit board and the configuration of the selector, after entering the diagnostic
mode, turn the programme selector dial clockwise to perform the diagnostic cycle for the operation of the
various components and to read any alarms.
Concurrently, a selector control code is shown on the LCD display, which indicates for two seconds the
description in the last column of the table below.
(all alarms are enabled in the diagnostic cycle).
Selector
position
- The LEDs, groups of symbols
in the LCD screen and the
backlight of the display are
turned on in sequence,
- Press a button/sensor to turn
1
on the group of icons in the
LCD screen or the
corresponding LED and
the buzzer sounds at the
same time.
- Door safety interlock
2
- Wash solenoid
- Door safety interlock
3
- Pre-wash solenoid
- Door safety interlock
4
- Solenoid valve
pre-wash and wash
- Door safety interlock
5
-
Third solenoid valve
T.S.-mdm FCPD-dp Quality tb
Components activated
Working conditions
Always active
Door closed
Water level below
anti-flooding level
Maximum time
5 mins.
Door closed
Water level below
anti-flooding level
Maximum time
5 mins.
Door closed
Water level below
anti-flooding level
Maximum time
5 mins.
Door closed
Water level below
anti-flooding level
Maximum time 5 mins.
8/61
Function tested
LCD display
User interface
functions
Water fill to wash
compartment
Water level in
the tub (mm)
Water fill to
pre-wash
compartment
Water level in
the tub (mm)
Water fill to
conditioner
compartment
Water level in
the tub (mm)
Water fill to third
solenoid valve
compartment
Water level in the
tub is displayed
(mm)
599 74 42-27 Rev.00