Guide to diagnostics of NEW COLLECTION EWM09312 electronic controls
EC4
Replace the main circuit board and run the diagnostic cycle to check for any further alarms.
EF1

EF1: Drain hose blocked/kinked/too high; drain filter clogged/dirty

This warning only appears at the end of the cycle. The appliance detected long drainage phases during
the cycle. (E.g.: More than 20 seconds when draining after rinses). Check/clean the drain filter.
EF2: Excessive detergent dosing; drain hose kinked/blocked;
EF2
This is an excessive detergent dosing warning. The system detected too much foam was forming
during the drain phases. Advise the Customer to use the correct quantity of detergent and to make sure
EF3
This warns about the presence of water at the bottom of the appliance. Check for any water leaks
Or caused by excessive overheating of the drain pump. Check for any items which may obstruct
EF4: Water pressure too low, no signal from flowmeter, with
EF4
This warning is for the water pressure which is too
If the water pressure is connect, check: the wiring of the flowmeter and the Flowmeter.
EF5
This is an unbalanced load warning. The appliance detected an extremely unbalanced load during the
spin phases. Advise the customer to load more washing into the drum and not just individual garments.
EF6
No action to be performed; if it continues, replace the main circuit board.
T.S.-mdm FCPD-dp Quality tb

EC4: AGS current sensor faulty error

Spin speed reduced to safety speed of 150 rpm
drain filter dirty/clogged
the filter and drain circuit are clean.

EF3: Aqua Control device triggered

and that the Aqua Control device float is positioned correctly.
the normal operation of the rotor.
electronically controlled valve open.

EF5: Unbalanced load, spin phases skipped.

EF6: Reset appliance.

!
Check that all the connectors are correctly inserted
If there are burns on the circuit board,
!
low.
Or the tap is closed.
54/61
EC4
see page 59
EF1
EF2
EF3
EF4
EF5
EF6