12. Disconnect the fan wiring harness
(Disconnect 1). Disconnect the over
temperature thermostat/light bulb wiring
harness (Disconnect 2).
13. Remove the 2 hex-head screws that hold the
fan bracket in place.
14. Remove the ground clip from the evaporator
frame.
15. Unclip the evaporator thermistor.
16. Slide the over-temperature thermostat/light
bulb wiring harness out of the fan bracket.
17. Remove the fan bracket.
Note: When replacing the evaporator thermistor,
cut the thermistor wires and splice the new
thermistor using bell connectors. Always use
RTV102 silicone to seal the end of the connec-
tor from moisture.
Freezer Evaporator
Parts Needed:
• Freezer Evaporator (part # WR85X10061)
• Drier Assembly (part # WR86X93)
• Access Tube (part # WJ56X61)
• Heat Shield Kit (part # WX5X8926)
Caution: A heat shield kit is required for this
procedure to prevent damage to the plastic
interior (liner) of the freezer compartment.
Note: If it is determined that the epoxy joints
(the transition joint between the aluminum and
copper jumper) on the freezer evaporator as-
sembly are defective, then
can be used to repair the joints. Refer to Pub.
No. 31-9067 for more
1. Unplug the refrigerator.
2. Remove the rear access cover and evacuate
the sealed system.
3. Remove components necessary to expose
the evaporator. (See
4. Remove the ice bucket, icemaker, auger
assembly, fan motor housing, and fan motor.
5. Note the location of thermistor and thermostat
on top of old evaporator and remove.
6. Remove heater from bottom of evaporator
and discard. Bundle remaining wires and tape
high on the back wall of freezer.
7. Apply a liberal amount of thermal paste to
suction line where it enters the rear wall of
freezer.
8. Insert the brazing shield behind the joint of
the accumulator top and suction line to pro
tect the liner.
9. Use torch to heat the joint of the accumulator
top, separate the suction line and accumula
tor top and clean the suction line surface (Fig.
1 and 2).
10. Using the tubing cutter, cut fresh food
evaporator jumper (right side) tube about 2
inches from the joint outlet end of the fresh
food evaporator. Score and break the capil
lary tube about 2 inches from the end of
freezer evaporator inlet jumper (left side)
(Fig. 1 and 2).