Before intervening on the handle unit, make a careful note of the
position of its various parts.
Loosen the screws that secure it to the back frame
23.3.3 Door safety interlock
Remove the iron ring securing the bellow seal to the cabinet.
Remove the part of the bellow seal concerned from the unit.
Unfasten the two screws securing the door safety interlock to the front
panel.
Cut the clamp (red arrow).
Remove the connector (blue arrow).
Recreate the initial conditions when re-assembling.