9 SHOCK ABSORBER, SWINGARM
63
Remove the screw of the filling port.
Install adapter ©
on
the damper.
©
k
o
{
u
Ns © '? i
©
Info
Tighten only hand-tight, without the use of tools.
I
i
'
k
\
i
Connect the adapter Q to connector
©
of the vacuum pump.
MM'
Vacuum pump (T1240S) (Si p. 333)
Clamp the damper with soft jaws or hold it as shown in the photo.
201286-10
Info
Clamp the damper only lightly.
The filling port must be at the highest point.
The piston rod slides in and out during filling - do not hold it tight with your
hand!
I
Place the control lever as shown in the photo.
i/" The External tank
0
control lever is on Closed, Damper ©
on
Vacuum,
and Oil reservoir © on Vacuum.
Operate the On/Off switch
©
y The vacuum pump process starts.
Pressure gauge © falls to the specified value.
_
y
i
©
/
• ®
O^M
** I
©
'
< 0 bar
The vacuum gauge © falls to the specified value.
200271-10
4 mbar
Measure distance
©
between the floating piston and reservoir hole with the spe­
cial tool.
Depth micrometer (T107S) (SS p. 332)
S The floating piston is positioned all the way at the bottom.
H
'Ti
©
Si
M
201285-10
When the vacuum pressure gauge reaches the specified value, turn the Oil reser­
voir control lever
0
to Equalize pressure.
Guideline
w
Chock all oil levels rogulnrly!
w
©
Closed
Pressure
Vacuum
4 mbar
^ The pressure gauge rises to the specified value.
Vacuum
Open
Equalize
pressure
0 bar
External
tank
Damper
Oil
tervoir
200267-10
^^XTioc^TranovoT^gTnarTyT
©
When the pressure gauge reaches the specified value, turn the Damper control
lever © to Pressure.
Guideline
17
1
Closed
Vacuum
ressure
0 bar
(BBSS
Equalize
pressure
S Oil is pumped into the damper.
S The pressure gauge rises to the specified value.
Open
Vacuum
Damper
Oil
External
tank
reservoir
3 bar
200268-10