Diagnostic Test Phases - Electrolux EWM0931 Series Service Manual

Table of Contents

Advertisement

3.3 Diagnostic test phases

Irrespective of the type of electrical board and of the selector configuration, once the diagnostics system
has been activated, turn the selector knob clockwise to run a check of the various components (as
described in table 1) and read the alarms.
A control code for the selector (or the second selector, where applicable) is shown at the same time: in
stylings A3 and Z3 on the display for two seconds, before displaying what is described in the last column of
the table below, whereas in stylings A5/6, Z5/6 and K6.2 the code is displayed by lighting the LEDs for
three seconds (see table 2 and 3).
All alarms are enabled in the diagnostic cycle.
Selector
position
- All the LEDS light up in
sequence.
1
- When you press a button,
the corresponding group or
LED lights up.
- Door safety interlock
2
- Wash solenoid
- Door safety interlock
3
- Pre-wash solenoid
- Door safety interlock
4
- Pre-wash and wash solenoid
- Door safety interlock
- Wash solenoid if the water
6
level in the tub does not cover
the heating element
- Heating element
- Door safety interlock
- Wash solenoid if the water
level in the tub does not cover
7
the heating element
- Motor (55 rpm clockwise,
- 55 rpm anticlockwise, pulse at
250 rpm)
- Door safety interlock
- Drain pump
8
- Motor up to 650 rpm then at
maximum spin speed (**)
9
----
10
- Reading/Deleting the last alarm
(*) In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating the phase without draining
the water: pass for a moment to a different phase of the diagnostic cycle and then back to the heating control phase (if the temperature
°
is higher than 80
C, heating does not take place).
(**) The check at the maximum speed occurs without control of the AGS and no garments must be inside the appliance.
2010 SOI/DT-mdm FCPD-dp Quality tb
Guide to diagnostics for electronic controls EWM0931x
Components activated
----
TABLE 1
Working conditions
Always active
Door closed
Water level below
anti-flooding level
Maximum time 5 mins
Door closed
Water level below
anti-flooding level
Maximum time 5 mins
Door closed
Water level below
anti-flooding level
Maximum time 5 mins
Door closed
Water level above
the heating element.
Maximum time
10 mins or up to
90°C. (*)
Door closed
Water level above
the heating element
Door closed
Water level lower
than anti-boiling level
for spinning
----
-----
8/67
Display, where
Function tested
featured
User interface
functions
Water fill to wash
compartment
Water level in
the tub (mm)
Water fill directly
to tub
Water level in
the tub (mm)
Water fill to
conditioner
Water level in
compartment
the tub (mm)
Heating
Temperature in
°C measured
using the NTC
probe
Check for leaks
from the tub
Drum speed in
rpm/10
Drain,
Calibration of
analogue
Drum speed in
pressure switch
rpm/10
and spin
----
----
599 72 97-24

Advertisement

Table of Contents
loading

Table of Contents