E83: Error reading the programme selector code

E83
Selector position code not envisaged by the configuration data or configuration error
Checks to perform:
Turn the appliance on, turn
the programme selector to
each setting: wait at least 10
seconds on each of the
settings before moving on to
the next one. Is alarm E83
shown again?
Y
E
S
Check for any friction
between the control panel
and the knob.
Is it difficult to turn the
knob?
Y
E
S
Repair the coupling between
the control panel/selector
knob.
Repeat the diagnostic cycle
to check for any further
E86
Checks to perform:
Replace the display board and run the diagnostic cycle to check for any further alarms.
2010 SOI/DT-mdm FCPD-dp Quality-tb
Guide to diagnostics for electronic controls EWM0931x
Check that all the connectors are inserted correctly
Repeat the diagnostic
cycle to check for any
NO
Replace the display board
and repeat the diagnostic
NO
cycle to check for any

E86: Programme selector configuration error

Check that all the connectors are inserted correctly
further alarms.
further alarms.
If there are burns on the circuit board,
57/67
there are burns on the circuit
board, see page 65
see page 65
E83
E86