11. Internal Switch Setting Method
The switches setting on each circuit board are shown below.
The switches "Factory use only" must be set to the "factory setting".
BOARD
F1: AUDIO
SW4100
SW4101
F6: SYSCON
SW301
F1: AUDIO circuit board
12. Internal LED Indication
BOARD
Ref. No.
F3A: SDI
D3200
(AJ-YA455P)
F7: SERVO
D350
D351
D352
F3A: SDI ( AJ-YA455P) circuit board
FACTORY
Ref. No.
SW
SETTING
-
HIGH
-
HIGH
1
OFF
2
OFF
SW101
For SDI input detection (light with SDI input/not light with no input)
Capstan servo lock: Light with lock/not light with unlock
Cylinder servo lock: Light with lock/not light with unlock
For servo microcomputer operation confirmation (flashing with a operating)
D3200
Aud io input inpedance setting (600 / HIGH)
Audio input inpedance setting (600 / HIGH)
Factory use only
Factory use only
F6: SYSCON circuit board
SW301
SW100
FEATURE
F7: SERVO circuit board
INF-26
FEATURE
D352
D350
D351