Technical Characteristics - Hot Water Mixing Heads - Electrolux KITWSRT Use And Installation Manual

Softener module
Table of Contents

Advertisement

USE AND INSTALLATION MANUAL

1.4.5. TECHNICAL CHARACTERISTICS - HOT WATER MIXING HEADS

SPECIFICATIONS / DESIGN CLASS
Valve body
Rubber components
Weight (valve with controller).
Recommended MIN - MAX working pressure
Hydrostatic pressure test
Water temperature for timed HW
Ambient temperature
Relative humidity
VALVE FITTINGS
Inlet/outlet ................................................................................................................................................1"
Rising pipe ....................................................................................................26.7 mm D.E., pipe 1.05"
Drainage pipe .......................................................................................................................... ½" D.E.
Brine line (1650)..........................................................................................................................⅜"
ELECTRICAL CHARACTERISTICS
Transformer output voltage.........................................................................................24 V CA, 10 VA max.
Motor input voltage......................................................................................................................24 V CA
Controller input voltage......................................................................................................................24 V CA
Max electrical consumption of controller ..............................................................................................................5
W
Protection rating ..................................................................................................................................IP 22
Temporary power surges ......................................................................................within limits of category II
Pollution level ....................................................................................................................................3
The temporary power surges must be limited both in duration and frequency.
MODEL
CYLINDER
SET SALT ADJUSTMENT
INJECTOR
DLFC
BLFC
12 LITRES/TIME
10"x17''
1.8 Kg
1
2.4
2.4
Brass
EP or EPDM
2.5 kg
1.4 - 8.6 bar
20 bar
1 - 82°C
5 - 40°C
80%
16