Display Fault Messages - GE NEMA User's Manual & Installation Instructions

Evse charging station
Table of Contents

Advertisement

g
EV Charging Station
(This picture depicts an example of all CLOSED dip switch positions. For correct settings, refer to below
tables)
The default settings per SKU are given in below table:
1
Factory
setting
CLOSED CLOSED
*) Language Settings
No Display or Set Language Via Config. Server
Spanish
French
English
**) Configuration Server
CLOSE = Normal operation
OPEN = Configuration server

3.5.2 Display fault messages

EVSE controller is capable of providing a full range of Fault troubleshooting options. When the
controller experiences a fault it will display the brief fault description message as well as the specific
fault code on the display.
Fault codes:
0x00000001
Fault indicating that the unit has experienced a ground fault and is waiting the required amount of
time (15 minutes) before it attempts to reclose the main contactor, clear the fault and continue
charging.
0x00000002
Fault indicating that the controller has experienced the maximum allowed number of ground faults
for a charge cycle.. To reset this fault simply disconnect the EVSE plug from the vehicle, and wait for at
least 30 seconds.
GE EV Charging Station User Manual
Figure 55: Dip Switch Settings
2
3
4
Factory
Factory
Factory
setting
setting
setting
CLOSED
OPEN
User Manual & Installation Instructions
5
6
7
reserved Language settings
CLOSED
OPEN *)
OPEN *)
6 position
Close
Close
Open
Open
Pushed down on "number"
side is the CLOSED position
8
Config.
server
CLOSE **)
7 position
Close
Open
Close
Open
55 of 86