Bosch B426 Installation And Operation Manual page 9

Conettix ethernet communication module
Table of Contents

Advertisement

Conettix Ethernet Communication
Module
Notice!
The module reads the address switch setting only during power up. If you change the
switches after you apply power to the module, you must cycle the power to the module in
order for the new setting to be enabled.
The B426 address switch provides the value for the module's address. The figure below shows
the address switch setting for address 1. Refer to the table below for panel-specific settings.
Figure 3.3: Address switch set to address 1
Control panels
Web-based configuration
setting
GV4 Series, B5512/B4512/
B3512
GV4 Series
GV4 Series, GV3 Series, GV2
Series, G Series v6.3 or
higher
GV4 Series, GV3 Series, GV2
Series, G Series v6.3 or
higher
GV4 Series, GV3 Series
DS7240V2, DS7220V2, Easy
Series V3+, AMAX 2000
DS7400Xi
DS7400Xi
FPD-7024
Table 3.1: B426 address switch settings
Notice!
You can use web browser configuration of the module's bus address setting only when the
switch is in the '0' position.
Bosch Security Systems, Inc.
Switch
B426 address Bus type
position
0
Configurable
1
1
2
2
3
80
4
88
5
92
6
134
7
13
8
14
9
250
Installation and Operation Guide (UL)
Function
Any
Web-based configuration
SDI2
Automation, RPS, or Reporting
SDI2
Automation, RPS, or Reporting
SDI
Automation
SDI
Reporting or RPS
SDI
Reporting or RPS
Option
Remote programming, Reporting
Option
Remote programming, Reporting
Option
Reporting
Option
Remote programming, Reporting
System overview | en
9
2013.08 | 02 | F.01U.281.208