System fans

The system fans provide cooling for the chassis. These fans circulate air through the chassis as
a means of lowering the chassis internal temperature.
1
Bosch Sicherheitssysteme GmbH
Place air shroud in the chassis. The air shroud fits behind the two fans closest to the
power supply.
Note: If a 16 DIMM (13.68" x 13") motherboard is used, it is necessary to use the optional
MCP-310-82502-0N air shroud.
Make sure there are no objects to obstruct airflow in and out of the chassis. In addition, if
you are using a front bezel, make sure the bezel's filter is replaced periodically.
Do not operate the system without drives or drive trays in the drive bays. Use only
recommended material.
Make sure no wires or foreign objects obstruct air flow through the chassis. Pull all
excess cabling out of the airflow path or use shorter cables. The control panel LEDs
inform you about system status.
System interface, page 10.
Air shroud, page 10.
Rack installation, page 23.